Flame Control · No. 60-60A · Spray foam

Cover your spray foam.
In one coat.

Building codes call for exposed spray polyurethane foam in lived-in spaces to be covered by a thermal barrier. Flame Control 60-60A is a water-based intumescent paint made for that job: one sprayed coat, no primer, and no drywall.

29:13CAN/ULC S-101-14 test
1 coatno primer needed
80sq ft per 3.79 L
$249+ships free in Canada

Tested on 4 in. of 2 lb/cu ft spray foam at 80 sq ft per gallon. Your local building official has the final say on what's accepted.

Flame Control No. 60-60A thermal barrier coating for spray polyurethane foam, white, 3.79 L
60-60A, WhiteThermal barrier for spray foam
Plan my job

Flame Control 60-60A Thermal Barrier Coating for Spray Foam Insulation

In stock - 9 items available
SKU: 60-60A-WH-01 UPC: 810333100014
Regular price $232.00 USD

Black Friday: extra 5% off in cart

Size
Color: White
✓ 10-Day Best Price Beat Guarantee: Found it cheaper? We'll beat it!

Flame Control 60-60A is a water-based intumescent thermal barrier coating for spray polyurethane foam insulation. Spray one coat, with no primer, over exposed foam in basements, garages, warehouses and other occupied spaces where codes call for a thermal barrier. Tested to CAN/ULC S-101-14 (29 min 13 s on 4 in. of 2 lb foam) and rated as a 15-minute thermal barrier under NFPA 286. Low VOC. White, grey or black, in 3.79 L and 18.9 L.

Key Features & Benefits

  • Thermal barrier for spray foam, tested to CAN/ULC S-101-14 and NFPA 286.
  • One coat, no primer in the tested system.
  • 80 sq ft per gallon at 20 mils wet.
  • Water-based, under 40 g/L VOC, no flash point.
  • Class A under CAN/ULC S-102.
  • Doesn't leach in high humidity.

Applications & Recommended Uses

Exposed spray polyurethane foam in occupied spaces: basements, garages, warehouses, roof assemblies and drop ceilings. Not tested for XPS or EPS foam board, or for wood (use Flame Control 20-20A). Your local building official decides what's accepted on your job.

Product Specifications

Testing CAN/ULC S-101-14; NFPA 286; IAPMO UES ER-596
Coverage 80 sq ft per 3.79 L
Film 20 mils wet, 10 dry
Dry time Touch 1–2 h; recoat 2–4 h
Apply at 10–30 °C
VOC Under 40 g/L
Colours White, grey, black
Sizes 3.79 L, 18.9 L

How to Use / Application Tips

  1. Clean, dry, firm foam; repair holes and exposed cells.
  2. Mix with a drill mixer until creamy.
  3. Spray one coat at 20 mils wet (80 sq ft per gallon).
  4. Clean up with water.

Why Buy From The Paint People?

We're a family-run paint store serving painting contractors in Mississauga since 1997. We ship across Canada, free on most orders over $249, or you can pick up in Mississauga. Not sure which fire retardant coating your job needs? Our team is happy to help.

FAQ
1Do I need a thermal barrier over spray foam?

Usually, yes. Building codes in Canada and the US call for foam plastic insulation in occupied spaces to be separated from the inside of the building by a thermal barrier. Drywall is the traditional one. 60-60A is a coating tested for that job. Your building official decides what's accepted on your project.

2Is 60-60A a 15-minute or a 25-minute thermal barrier?

You'll see both. In the US, it's a 15-minute thermal barrier under NFPA 286. In Canada, it was tested to CAN/ULC S-101-14, where the test ran 29 minutes 13 seconds on 4 in. of 2 lb foam at 80 sq ft per gallon, and Flame Control Canada calls it a 25-minute thermal protective layer. Show your official the Canadian data sheet.

3How much do I need?

One 3.79 L can covers 80 sq ft in one coat, and an 18.9 L pail about 400 sq ft. For 1,000 sq ft of foam, that's 12.5 gallons: two pails plus three cans. Add about 10% for spray loss. Use the calculator above.

4Do I need a primer?

Not in the tested system. Prime areas that will see continuous high humidity. Some foams, especially ones that dry glossy, may also need a primer, so Flame Control suggests a spot test.

Canada Shipping

  • Enjoy free shipping in Canada on orders over $249. Yukon, NWT, Nunavut not included.

Winter Shipping:

  • From December to April, shipping outside of Ontario and Quebec is limited.
  • Returns accepted within 35 days from the date of delivery.
  • Custom tinted paints are classified as Final Sale items and are not eligible for return or store credit.

How it works

A thermal barrier you can spray.

Spray foam insulates well, but it has to be separated from the room. 60-60A goes straight onto the foam and, in a fire, swells into an insulating char that slows heat and flame reaching it.

01

One coat, no primer

Spray a single coat at 20 mils wet (10 mils dry), about 80 sq ft per gallon. The tested system uses no primer and no topcoat.

02

Swells into a char

On contact with flame or high heat, the coating intumesces into a thick, insulating layer. In the Canadian test, flames on the foam went out as soon as the flame source was removed.

03

Tested in Canada and the US

CAN/ULC S-101-14: ran 29 min 13 s on 4 in. of 2 lb foam at 80 sq ft/gal. Class A under CAN/ULC S-102. A 15-minute thermal barrier under NFPA 286 and IAPMO UES ER-596.

Flame Control's Canadian data sheet references the National Building Code of Canada 2020 (Div. B, 3.1.5.15) and the Ontario Building Code. Water-based, under 40 g/L VOC, no flash point. White, grey or black.

Where it goes

Right on the foam.

60-60A is sprayed directly onto spray polyurethane foam, where codes would otherwise call for a barrier like drywall. Use it in basements, garages, warehouses, roof assemblies and other spaces with exposed foam.

Use it on

  • Spray polyurethane foam, in occupied spaces
  • Clean, dry, firm foam, with holes and exposed cells repaired
  • Humid areas, with a primer first

Not for

  • Foam board like XPS or EPS: it was tested on spray foam
  • Wood or plywood: use 20-20A
  • Below 10 °C, or foam that's wet or dusty

Coverage calculator

How much do I need?

Enter the foam area. We use 80 sq ft per gallon, the rate in Flame Control's Canadian test, and switch to 18.9 L pails when they work out cheaper.

ft
ft
ft
You need
—

Coverage is 80 sq ft per 3.79 L, or about 400 sq ft per 18.9 L pail, in one coat. Some foam brands are tested at other rates, so use the rate your foam's report lists if it differs.

Compare

Which Flame Control do I need?

60-60A is the one for spray foam. For wood, plywood and OSB, you want a fire retardant paint instead.

Spray foam

Flame Control 60-60A

Best for
Exposed spray polyurethane foam in lived-in spaces.
What you get
A one-coat intumescent thermal barrier, sprayed at 80 sq ft per gallon.
From
 
You're here
Interior wood

Flame Control 20-20A

Best for
Interior wood, plywood, OSB and other combustible surfaces.
What you get
Class A flat paint, white or black, in one or two coats.
From
 
See 20-20A →
Exterior wood

Exterior Guard Basecoat

Best for
Lumber, plywood and OSB going under siding or cladding.
What you get
The exterior version of 20-20A, Class A, with an exterior topcoat when exposed.
From
 
See Exterior Guard →

See every fire retardant coating we carry in fire retardant & intumescent coatings, or the whole Flame Control range.

Specs

The details.

TypeWater-based intumescent thermal barrier coating
Fire testingCAN/ULC S-101-14: 29 min 13 s on 4 in. of 2 lb/cu ft foam. CAN/ULC S-102 Class A. NFPA 286 15-minute thermal barrier. IAPMO UES ER-596 (AC456/AC377)
Use onSpray polyurethane foam in occupied spaces
ColourWhite, grey or black. Matte finish
Coverage80 sq ft per 3.79 L (1.95 m²/L), one coat. About 400 sq ft per 18.9 L
Film thickness20 mils wet, 10 mils dry
PrimerNone in the tested system. Required in areas of continuous high humidity
Dry timeTouch 1–2 hours. Recoat 2–4 hours. Use fans at 65% humidity or higher
Apply at10–30 °C (50–86 °F)
VOCUnder 40 g/L
Solids51% ± 2 by volume, 65% ± 2 by weight
Spray rigAirless, 3,300 psi, 1.35 GPM, 517–533 tip, filters removed, 3/8" hose for the first 50 ft plus a ¼" × 6 ft whip
Minimum rig3,000+ psi, 0.95 GPM, 517–531 tip
Clean-upWater
Shelf life12 months unopened. Store above 10 °C and never let it freeze

From Flame Control's Canadian product data sheet. Dry times at 25 °C (77 °F) and 50% humidity.

How to apply

One coat, done right.

  1. Check the foam. It must be clean, dry and firm, with no dust, dirt, grease, oil or mould. Scrub mould with a 25% household bleach solution, rinse and let it dry.
  2. Repair it. Fill holes and fix exposed cells or crumbling areas before you coat.
  3. Prime only if needed. Prime areas that see continuous high humidity. Foams that dry glossy may also need it, so do a spot test.
  4. Warm the space and the paint. Apply between 10 and 30 °C. Run fans if humidity is 65% or higher.
  5. Mix it well. Use a drill mixer, bottom to top, scraping the sides, until it's creamy with no lumps. Poor mixing weakens the protection.
  6. Spray one full coat. Apply 20 mils wet (80 sq ft per gallon) and check it with a wet film gauge. Clean up with water.

FAQ

Spray foam thermal barrier questions, answered.

Do I need a thermal barrier over spray foam?

Usually, yes. Building codes in Canada and the US call for foam plastic insulation in occupied spaces to be separated from the inside of the building by a thermal barrier. Drywall is the traditional one. 60-60A is a coating tested for that job. Your building official decides what's accepted on your project.

Is 60-60A a 15-minute or a 25-minute thermal barrier?

You'll see both. In the US, it's a 15-minute thermal barrier under NFPA 286. In Canada, it was tested to CAN/ULC S-101-14, where the test ran 29 minutes 13 seconds on 4 in. of 2 lb foam at 80 sq ft per gallon, and Flame Control Canada calls it a 25-minute thermal protective layer. Show your official the Canadian data sheet.

How much do I need?

One 3.79 L can covers 80 sq ft in one coat, and an 18.9 L pail about 400 sq ft. For 1,000 sq ft of foam, that's 12.5 gallons: two pails plus three cans. Add about 10% for spray loss. Use the calculator above.

Do I need a primer?

Not in the tested system. Prime areas that will see continuous high humidity. Some foams, especially ones that dry glossy, may also need a primer, so Flame Control suggests a spot test.

Can I roll or brush it on?

Yes, but spraying is the preferred method and gives the best results. Whatever you use, you need the full 20 mils wet across the whole surface. Check it with a wet film gauge.

What sprayer do I need?

Flame Control recommends an airless sprayer like a Graco Mark IV or V: 3,300 psi, 1.35 GPM, a 517–533 tip, filters removed, and a 3/8 in. hose for the first 50 ft. The minimum is 3,000 psi and 0.95 GPM. See our airless sprayers, or ask our Rockwood Village spray centre about rentals.

Can I use it on XPS or EPS foam board?

60-60A was tested and listed on spray polyurethane foam, not on rigid polystyrene boards like XPS or EPS. If you're covering foam board, talk to your building official first, and ask us before you order.

Does it work on open-cell and closed-cell foam?

The Canadian test used 4 in. of 2 lb/cu ft spray foam. Flame Control has also tested 60-60A with specific foam brands, and some list their own rate. Check your foam maker's evaluation report, and apply at the rate it gives.

Can I put a topcoat on it?

You don't need one. The tested system has no topcoat. You can add one to protect the colour and guard against moisture.

How cold can it be?

Apply between 10 and 30 °C. Store it above 10 °C: it's water-based and can't be used once it freezes. From December to April, shipping outside Ontario and Quebec is limited, so plan winter jobs ahead.

Thermal barrier, sorted.

Not sure which fire retardant coating your job needs? Ask our team. We've been helping painters and contractors since 1997.