Flame Control · No. 20-20A · Interior
Paint that slows
the flames.
Flame Control 20-20A is a water-based intumescent paint that gives interior wood, plywood and OSB a Class A flame spread rating under CAN/ULC S-102. It rolls on like ordinary flat latex. In a fire, it puffs up into a thick, insulating foam.
Ratings apply at the tested coverage rate. Check with your local fire or building official before you buy.

Peinture ignifuge intumescente à base d'eau Flame Control, classification A, 20-20A
Black Friday: extra 5% off in cart
Impossible de charger la disponibilité du service de retrait
Contrôle de Flamme No. 20-20A : Peinture Ignifuge avec Protection Avancée :
Le contrôle des flammes n° 20-20A est une peinture ignifuge de qualité supérieure conçue pour offrir une protection incendie intérieure exceptionnelle sans compromettre l'apparence. Cette peinture à base d'eau, à faible teneur en COV, de type latex mat, offre des mesures de sécurité avancées tout en conservant l'aspect et la sensation de la peinture latex mate conventionnelle. Conçue conformément à la spécification fédérale TT-P-001932, elle garantit qualité et fiabilité.
Le contrôle de flamme n° 20-20A est le choix idéal pour quiconque recherche une protection incendie fiable pour les surfaces intérieures. Testé, approuvé et durable—ce n'est pas juste de la peinture ; c'est la tranquillité d'esprit.
Caractéristiques :
- Protection contre le feu inégalée
- Atteint un Classe "A" évaluation per ASTM E-84-05 Test de 10 minutes.
- Fournit un Classement de feu de 30 minutes lorsque deux couches sont appliquées aux taux recommandés, testées selon ASTM E-84-10 Test Étendu.
- Technologie intumescente innovante
- Lorsqu'il est exposé à une chaleur extrême ou à des flammes, la peinture forme une épaisse couche de mousse spongieuse. Cette barrière intumescente protège le substrat en isolant contre la chaleur et en ralentissant la propagation des flammes, retardant ainsi de manière significative les dommages structurels.
- Application Flexible
- Peut être utilisé un revêtement supérieur ou amélioré avec le revêtement résistant au feu à faible brillance Latex Flame Control No. 40-40A pour une protection et un style supplémentaires.
- Convivial
- La formulation à faible teneur en COV est facile à appliquer, sèche rapidement et offre une finition lisse et mate idéale pour les espaces intérieurs modernes.
Informations sur la performance :
▪ Classe "A" de résistance au feu.
▪ Conforme aux exigences fédérales, étatiques, locales en matière de construction et de code de la sécurité incendie.
▪ Sèche par évaporation de l'eau pour un fini mat, flexible et résistant.
▪ Ne perd pas (perte de résistance au feu) lors d'une exposition à une forte humidité.
▪ Répond à toutes les réglementations sur les COV, y compris celles de la SCAQMD.
Canada Shipping
- Enjoy free shipping in Canada on orders over $249. Yukon, NWT, Nunavut not included.
Winter Shipping:
- From December to April, shipping outside of Ontario and Quebec is limited.
- Returns accepted within 35 days from the date of delivery.
- Custom tinted paints are classified as Final Sale items and are not eligible for return or store credit.
How it works
Looks like paint. Acts like a shield.
20-20A goes on like a flat latex. The difference shows up in a fire: the film swells into a sponge-like foam that keeps heat and flame away from the wood underneath.
Rolls on like flat latex
Brush, roll or spray it. It dries to the touch in 30 minutes to a flat white or black finish.
Swells in a fire
Heat makes the coating intumesce into a thick cellular foam. That layer insulates the surface and slows flame spread, heat and structural damage.
Rated at the right rate
Class A at 155 sq ft per 3.78 L in one or two coats. Two coats at 200 sq ft per can each have been tested for 30 minutes.
Low VOC (45 g/L) with water clean-up. Won't lose its fire retardancy in high humidity. Made to US Federal Specification TT-P-001932. Can also go outside where it's protected from the weather, such as under siding.
What Class A means
A low number is what you want.
Flame spread is measured in a tunnel test (CAN/ULC S-102 in Canada, ASTM E-84 in the US). Class A is a flame spread index of 25 or less.
Results from Flame Control's Canadian product data sheet. A 30-minute test on Douglas fir plywood (two coats at 200 sq ft per gallon) ran the full 30 minutes with no significant progressive combustion.
Coverage calculator
How much do I need?
Enter your room or your total square footage. We work it out at Flame Control's tested rate for the rating you need, so you don't come up short.
Class A: 155 sq ft per 3.78 L, in one or two coats. 30-minute: two coats at 200 sq ft per can each, so about 100 sq ft per can in total. Measure only the surfaces you need to rate.
Compare
Which Flame Control do I need?
Pick by what you're coating. Fire retardant paints slow flame spread on wood. A thermal barrier protects spray foam.
Flame Control 20-20A
- Best for
- Interior wood, plywood, OSB and other combustible surfaces.
- What you get
- Class A flat paint, white or black, in one or two coats.
- From
Exterior Guard Basecoat
- Best for
- Lumber, plywood and OSB going under siding or cladding.
- What you get
- The exterior version of 20-20A, Class A, with an exterior topcoat when exposed.
- From
INSL-X FR-210
- Best for
- Interior walls, ceilings and trim in a white flat finish.
- What you get
- Benjamin Moore's Class A intumescent latex, for wood, drywall, plaster, masonry and metal.
- From
See every fire retardant coating we carry in fire retardant & intumescent coatings, or the whole Flame Control range.
Specs
The details.
| Type | Water-based flat latex intumescent fire retardant paint |
|---|---|
| Fire rating | Class A, CAN/ULC S-102 (ASTM E-84). Up to 30 minutes per NFPA 703 and BOCA 1702-4.1 |
| Use on | Interior combustible surfaces: wood, plywood, OSB, fibreboard. Exterior only where protected from weather |
| Colour | White or black. Takes up to 2 fl oz universal tint per gallon |
| Finish | Flat (5 units max @ 60°) |
| Coverage | 155 sq ft per 3.78 L (3.8 m²/L), one or two coats |
| Film thickness | 10.4 mils wet, 4.8 mils dry |
| Dry time | Touch 30 min. Handle 1–2 hours. Recoat 2–4 hours |
| Apply at | 10 °C (50 °F) or warmer, air and surface |
| VOC | 45 g/L |
| Solids | 46% ± 2 by volume, 59% ± 2 by weight |
| Apply with | Brush, roller, conventional or airless spray (2,500 psi, .021–.026 tip, 80 mesh, ¼" hose) |
| Thinning | Water only, up to ½ pint per gallon. Thinned paint must go on heavier to keep the rating |
| Topcoat | Not usually needed. For washability or another colour, Flame Control 40-40A or a good latex |
| Clean-up | Water |
| Shelf life | 24 months unopened. Protect from freezing |
From Flame Control's Canadian product data sheet. Dry times at 25 °C (77 °F) and 50% humidity.
How to apply
Rated coats, done right.
- Clean the surface. Remove dirt, grease, oil, wax, rust and anything else that would stop the paint from bonding.
- Prime new wood. Seal new wood, fibreboard and porous surfaces with a good-quality primer such as INSL-X Prime All and let it dry. Prime metal with a universal metal primer; Flame Control hasn't rated 20-20A on metal.
- Prep old paint. Sound, tightly bonded paint is fine. Sand glossy areas dull and spot-prime bare spots.
- Warm it up and stir. Air and surface must be 10 °C or warmer. Stir or box the paint well.
- Apply at the rated rate. A full coat at 155 sq ft per can (10.4 mils wet), in one or two coats. For 30 minutes, two coats at 200 sq ft per can each.
- Clean up with water. Recoat after 2–4 hours. Keep leftover paint from freezing.
FAQ
Fire retardant paint questions, answered.
What is Flame Control 20-20A?
A water-based, low VOC, flat latex fire retardant paint for interior combustible surfaces. It looks like a regular flat paint, but in a fire it swells into a thick foam that insulates the surface and slows flame spread. It's rated Class A under CAN/ULC S-102.
What does Class A mean?
Class A means a flame spread index of 25 or less in the tunnel test (CAN/ULC S-102 in Canada, ASTM E-84 in the US). On Douglas fir, 20-20A scored a flame spread of 5 and smoke developed of 40 at 155 sq ft per gallon.
How much do I need?
For Class A, one 3.78 L can covers 155 sq ft, in one or two coats. For the 30-minute rating, apply two coats at 200 sq ft per can each, which works out to about 100 sq ft per can. Use the calculator above for your room.
Will a thicker coat give me a longer fire rating?
No. Fire ratings come from specific tested systems at specific rates. Putting on more paint than the tested rate doesn't raise the rating. Apply at the rate your rating calls for and check it with a wet film gauge.
Can I paint over it?
You don't usually need to. For more washability or a different colour, Flame Control says to topcoat with its 40-40A Fire Resistant Topcoat or a good-quality latex. The tested topcoat system uses 40-40A, and we can special-order it for you.
Can I use it on drywall, steel or masonry?
It's made for combustible surfaces like wood, plywood, OSB and fibreboard. Metal must be primed, and Flame Control hasn't determined a fire rating on metal. For white walls and ceilings over drywall, plaster or masonry, look at INSL-X FR-210.
Can I use it outside?
Only where it's protected from the weather, such as under siding. For exterior wood, Exterior Guard Basecoat is Flame Control's exterior version, with an exterior topcoat when it's exposed.
Is this a heat resistant paint for stoves or heaters?
No. 20-20A is a fire retardant paint: it slows flame spread on combustible building surfaces. It isn't made for hot surfaces like stoves, heaters or exhaust parts. Those need a high-heat coating.
How fast does it dry?
Dry to the touch in 30 minutes, ready to handle in 1–2 hours and ready to recoat in 2–4 hours at 25 °C and 50% humidity. Apply it only when the air and surface are 10 °C or warmer.
Will it pass my inspection?
That's up to your local fire or building official, who decides what's accepted on your job. Show them the rating you need and Flame Control's data sheet before you buy, and apply at the tested rate.
Get the rating right the first time.
Not sure which fire retardant coating your job needs? Ask our team. We've been helping painters and contractors since 1997.